
Technical library
Apparent density and particle size
Apparent density and particle size set how much carbon fits in a vessel and how it behaves in a bed.
Apparent density and particle size set how much carbon fits in a vessel and how it behaves in a bed.
Apparent density (ASTM D2854)
The weight of a unit volume of loosely poured carbon. Our granular grades range from about 0.46 to 0.52 g/cc. Use it to work out how many kilograms fill a given vessel.
Particle size (ASTM D2862)
Granular carbon is graded by mesh. 6x12 means granules pass a 6 mesh screen and are retained on 12 mesh. We make 3x6, 4x8, 6x12, 8x16, 8x30, 12x30 and 30x60.
Why it matters
Coarse sizes give low pressure drop. Fine sizes adsorb faster. Tight size ranges give even flow through a bed.
What to specify
Mesh range, the oversize and undersize limits, and the apparent density range.